CT-1600 Series Encapsulated. 50Hz/ 60 Hz Operating Frequency
|
CT-1600
Series Current Sense Transformer (AC).
Customer install single turn primary to make current sense transformer
|
FEATURES:
- Pre-set secondary winding for most common application
- Burden Resistor (RL) = 100 Ohms
- Max DC Resistance Range@ 25 deg C = (45 to 50) Ohms
- Output Voltage Range at RL @ Nominal Current Range=( 2 to 4) V rms
- Accuracy Class Range = +- 0.5%
- Primary Current Range = ( 20 to 40) Amps rms Nominal
- Primary Current Range = ( 60 to 100) Amps rms Max
- Max Amplitude Error = 5% of Nominal Current Value
- Designed for 50 Hz to 60 Hz current sensing applications
- Applications, Energy (Kilowatt Hour Electricity) Meters, Electricity Dispensers, Power Calibrator, Power Transducer, Precision Power Meters, Digital Meters For Power Systems, Servo Motors
- Encapsulated construction for robust operation
|
|
|
|
SPECIFICATIONS
IMPORTANT
1) No tooling or set up fees required for standard parts
2) Minimum order : 10 Pieces. Samples available
for large OEMs
3) Typical Delivery: 3 to 6 weeks
|
| |
CONSTRUCTION INFORMATION
Please see pdf files for details.
See link below for some sample PDF files.
CT-1601-ST
CT-1602-ST
|
|
Part
Numbering
|
CT-1601-ST
CT : Current Sensor Type
1601 : Series
ST : Standard Accuracy
|
|
|
|
Notes:
1
) The prices
shown below are for low volume quantity. Please call 800-377-3244
or
email sales@coilws.com for larger
volume OEM pricing.
2 ) Our large
OEM pricing is extremely competitive. We will meet or beat any competitors
prices with better deliveries 3
) Custom designs
are available to meet any of your requirements. Please contact us
4
) The data shown below can be sorted by clicking each column header.Click once again to sort in reverse order.
5) Stock Quantity shown is available for immediate shipment. Qty shown is valid on Date shown and is subject to priro sales. Production qty lead time is 4 to 6 weeks.
|
Displaying 1 to 3 (of 3 products)
(Searching Part Numbers, Inductance, Current fields)
Displaying 1 to 3 (of 3 products)
|
|
Need
Power Inductors? CWS delivers the finest in surface mount inductors
and standard inductors, power transformers, Common Mode Chokes,
Ceramic Chip Inductors and Wire Wound Chip Inductors. CWS can
supply all of your filtering needs as well, including EMI Filters,
RFI Filters, LC Filter Inductors, and Common Mode Filters. From
Transmission Line Transformers to power transformers, CWS is the
source to call!
Disclaimer: Coilws.com, Inc. reserves the right at any time and from
time to time to make changes to design, technical specification, or
construction of any product listed on this website without notice. Coilws.com,
Inc. also reserves the right to discontinue or limit sale of any product or
service available throughout this website on temporary or permanently basis without notice. Coilws.com, Inc. highly recommend customers not to use its products offered on this website for inappropriate use and applications. Products should be tested for its suitability by prospective customers in all possible applications and conditions.
Please note: Cross References are only equivalent products and may have some variations. In no way cross references can be interpreted as precise reproduction of products offered by cross reference supplier.
Your
comments and suggestions are important to us, please feel free to email
us at : sales@coilws.com
Call us Toll Free: 1(800) 377-3244
Copyright © 2008, Coilws.com, Inc
Updated Jan, 2008