---- April 25th 2024 ----

www.ccr.gov
CAGE Code: 5DME2
ITAR Registration Code: M28889
Call: 1 (800) 377-3244
Monday to Friday 8 A.M. - 5 P.M. (Pacific Time)
E-mail questions and requirements to: sales@coilws.com

Pricing is subject to change depending on product availability and backorders.
*Please Note: Items without price are listed for CWS' capability purposes.

AppNotes - Understanding EMC Stands and Specifications Page 2 (E


          EN 50081-1:1992 Emission/Residential, commercial and light industry
Part Frequency Range Limits Basic Standard Remarks
Enclosure







AC Mains




30-230MHz
230-1000MHz

0-2kHz

0.15-0.5MHz
Limits decrease linearly
with log frequency
0.5-5MHz

5-30MHz

0.15-30MHz
30dB(uV/m)
37dB(uV/m)



66-56dB(uV)
56-46dB(uV)

56dB(uV)
46dB(uV)
60dB(uV)
50dB(uV)
See basic standard
EN 55022
Class B

EN 60555-2
EN 60555-3
EN 55022
Class B





EN 55014
The statistical
evaluation in the basic
standard applies


The statistical
evaluation in the basic
standard applies





¥












Application Note
¥ =          Applicable only for apparatus containing processing devices.
† =          Applicable to apparatus covered within the scope of EN 60555-2 and EN 60555-3.                Limits for apparatus not currently covered by EN 60555-2 and EN 60555-3 are under                consideration.
Annex A
Part Frequency Range Limits Basic Standard Remarks
Signal Control
DC Power Input
DC Power Output
& Other

0.15-0.5MHz
limits decrease linearly
with log requency
0.5-30MHz

40-30mB(µA) quasi peak
30-20dB(µA) average

30dB(µA) quasi peak
20dB(µA) average
CISPR
Publication 22
Amendment under
consideration Class B

Current probe
measurement with line
terminated to reference
plane via 150W

 

Disclaimer: Coil Winding Specialist, Inc., its affiliates, agents, and employees acting on behalf of Coil Winding Specialist, Inc. (collectively, CWS) disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. CWS reserves the right at any time and from time to time to make changes to design, technical specification, or construction of any product listed on this website without notice. CWS also reserves the right to discontinue or limit sale of any product or service available throughout this website on temporary or permanently basis without notice. CWS highly recommends customers not to use its products offered on this website for inappropriate use and applications. Products should be tested for its suitability by prospective customers in all possible applications and conditions. Customers using or selling CWS products for use in other than recommended applications do so entirely at their own risk and agree to fully indemnify CWS from any damages arising or resulting from such use or sale.

WARNING: This product can expose you to chemicals which is [are] known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go towww.P65Warnings.ca.gov.


Any Comments, Suggestions or Questions? Contact us!
Email: sales@coilws.com
CWS 353 West Grove Ave. Orange, California 92865
Call us Toll Free: 1-800-679-3184 or 1 (800) 377-3244

Tel: (714) 279-9010, Fax: (714) 279-9482

Copyright 2008, Coil Winding Specialist, Inc
Updated July, 2013

CAGE Code: 5DME2(Registered with www.ccr.gov)